> ## Content Index
> Fetch the complete content index at: https://skills.devopscube.com/llms.txt
> Use this file to discover other available public pages before exploring further.

# Mount a Volume Into a Pod Using Kubernetes PV, PVC and SC
- URL: https://skills.devopscube.com/mount-a-volume-into-a-pod-using-pv-pvc-and-sc/
- Published: 2026-09-17T14:53:25.000Z
- Updated: 2026-10-14T10:42:17.000Z
- Author: Sulaiman
- Tags: #CKA-Exam-question, #blog, #docs, Storage

You are a DevOps engineer at Devopscube working on a new microservices-based application named `Tekion`. The application requires persistent storage for one of its components.

Your task is to configure Kubernetes persistent storage using a StorageClass, PersistentVolume, PersistentVolumeClaim, and Pod.

Configure and verify the following resources in the Kubernetes cluster:

1. Create a StorageClass named `tekion-sc` using the `kubernetes.io/no-provisioner` provisioner and a `Retain` reclaim policy.
2. Create a PersistentVolume named `tekion-pv` with:
  - Capacity: 5Gi
  - StorageClass: `tekion-sc`
  - Access mode: ReadWriteOnce (RWO)
  - Host path: `/tmp/data`
1. Create a PersistentVolumeClaim named `tekion-pvc` that requests 2Gi of storage and is bound to `tekion-pv`.
2. Create a Pod named `tekion-pod` using the `nginx` image.
3. Mount the PVC inside the Pod at `/app/data`.

📚

For more details on [PV](https://kubernetes.io/docs/concepts/storage/persistent-volumes/?ref=skills.devopscube.com), [PVC](https://kubernetes.io/docs/reference/kubernetes-api/core/persistent-volume-claim-v1/?ref=skills.devopscube.com), and [SC](https://kubernetes.io/docs/concepts/storage/storage-classes/?ref=skills.devopscube.com), refer to the official Kubernetes documentation.

---

### Create the StorageClass

Create a file named `tekion-sc.yaml`:

💡

If you’re unsure about the YAML structure or syntax, check the official Kubernetes documentation for a clear reference.

tekion-sc.yaml Copy 

apiVersion: storage.k8s.io/v1 kind: StorageClass metadata:  name: tekion-sc provisioner: kubernetes.io/no-provisioner reclaimPolicy: Retain 

Apply the manifest:

```sh
$ kubectl apply -f tekion-sc.yaml

storageclass.storage.k8s.io/tekion-sc created
```

Verify the StorageClass:

```sh
$  kubectl get storageclass

NAME        PROVISIONER                    RECLAIMPOLICY   VOLUMEBINDINGMODE   ALLOWVOLUMEEXPANSION   AGE
tekion-sc   kubernetes.io/no-provisioner   Retain          Immediate           false                  12s
```

You should see `tekion-sc` with the `kubernetes.io/no-provisioner` provisioner and `Retain` reclaim policy.

## Why is `kubernetes.io/no-provisioner` used?

`kubernetes.io/no-provisioner` indicates that Kubernetes should not dynamically provision storage for this StorageClass. Instead, the administrator manually creates the PersistentVolume. In this exercise, that manually created PV is `tekion-pv`.

### Create the Kubernetes Persistent Volume

Create a file named `tekion-pv.yaml`:

persistent-volume.yaml Copy 

apiVersion: v1 kind: PersistentVolume metadata:  name: tekion-pv spec:  capacity:  storage: 5Gi  storageClassName: tekion-sc  accessModes:  \- ReadWriteOnce  hostPath:  path: /tmp/data 

Apply the manifest:

```sh
$ kubectl apply -f tekion-pv.yaml

persistentvolume/tekion-pv created
```

Verify the PV:

```sh
$ kubectl get pv

NAME        CAPACITY   ACCESS MODES   RECLAIM POLICY   STATUS      CLAIM   STORAGECLASS   VOLUMEATTRIBUTESCLASS   REASON   AGE
tekion-pv   5Gi        RWO            Retain           Available           tekion-sc      <unset>                          39s
```

You should see `tekion-pv` with **5Gi** capacity and a **STATUS of `Available`**, since no PVC has been created yet.

### Create the Kubernetes persistent storage

Create a file named `tekion-pvc.yaml`:

tekion-pvc.yaml Copy 

apiVersion: v1 kind: PersistentVolumeClaim metadata:  name: tekion-pvc spec:  accessModes:  \- ReadWriteOnce  storageClassName: tekion-sc  resources:  requests:  storage: 2Gi 

Apply the manifest:

```sh
$ kubectl apply -f tekion-pvc.yaml

persistentvolumeclaim/tekion-pvc created
```

Now check both the PV and PVC:

```sh
$ kubectl get pv 

NAME        CAPACITY   ACCESS MODES   RECLAIM POLICY   STATUS   CLAIM                STORAGECLASS   VOLUMEATTRIBUTESCLASS   REASON   AGE
tekion-pv   5Gi        RWO            Retain           Bound    default/tekion-pvc   tekion-sc      <unset>                          4m59s

$ kubectl get pvc

NAME         STATUS   VOLUME      CAPACITY   ACCESS MODES   STORAGECLASS   VOLUMEATTRIBUTESCLASS   AGE
tekion-pvc   Bound    tekion-pv   5Gi        RWO            tekion-sc      <unset>                 2m7s
```

The PVC and PV should both show**`STATUS: Bound`**, confirming that the PVC has successfully claimed the PV.

The claim can bind to the PV because the PV has enough capacity to satisfy the requested storage.

<!DOCTYPE html> 

## Understand the PV and PVC Relationship

The StorageClass defines the storage type, the PV (tekion-pv) provides 5Gi, and the PVC (tekion-pvc) requests 2Gi. Once the PVC binds to the PV, the Pod can use the storage through `/app /data`.

### Create the Pod

You can generate a basic Pod manifest using:

```sh
kubectl run tekion-pod \
  --image=nginx \
  --dry-run=client -o yaml > tekion-pod.yaml
```

Edit `tekion-pod.yaml` and add the PVC volume and volume mount.

The final manifest can be:

tekion-pod.yaml Copy 

apiVersion: v1 kind: Pod metadata:  name: tekion-pod spec:  containers:  \- name: tekion-pod  image: nginx  volumeMounts:  \- name: tekion-volume  mountPath: /app/data  volumes:  \- name: tekion-volume  persistentVolumeClaim:  claimName: tekion-pvc 

The important configuration is the connection between the volume mount and the PVC. The Pod mounts `tekion-volume` at `/app/data`, while the `volumes` section connects the same volume to `tekion-pvc` using `persistentVolumeClaim`. The volume name must match in both sections.

It must match the PVC name `tekion-pvc`. This connects the Pod to the PVC and mounts the storage at `/app/data`.

### Deploy the Pod

Apply the Pod manifest:

```yaml
$ kubectl apply -f tekion-pod.yaml

pod/tekion-pod created
```

Verify the Pod:

```sh
$ kubectl get pod tekion-pod

NAME         READY   STATUS    RESTARTS   AGE
tekion-pod   1/1     Running   0          2m1s
```

The Pod should be running successfully with the container ready.  
The PV and PVC should both be in the Bound state, while the Pod should be Running. This confirms that the storage chain is configured and working correctly.

### Verify the Volume Mount

Following this command

```sh
kubectl describe pod tekion-pod
```

Look for the `Mounts` section.

You should see information similar to:

```sh
Mounts:
      /app/data from tekion-volume (rw)
```

The `Volumes` section should show:

```sh
Volumes:
  tekion-volume:
    Type:       PersistentVolumeClaim
    ClaimName:  tekion-pvc
```

This confirms that the Pod is using `tekion-pvc`.

### Verify the Mount Inside the Container

You can also verify that `/app/data` exists inside the nginx container:

```
kubectl exec tekion-pod -- ls -ld /app/data
```

You should receive output showing the `/app/data` directory.

You can also inspect the mounted filesystem:

```
kubectl exec tekion-pod -- df -h /app/data
```

## CKA Exam Tips

These tips will help you quickly identify the important Kubernetes concepts and avoid common mistakes during the exam.

## Tip 1: Check the StorageClass API Version

Make sure the StorageClass uses the correct API version: `storage.k8s.io/v1`.

## Tip 2: Match the StorageClass

The storageClassName must match in both the PV and PVC, such as `tekion-sc`.

## Tip 3: Check the Mount Path

Make sure the volume is mounted at the required path: `/app/data`.

## Tip 4: Check Kubernetes PV and PVC

Use `kubectl get pv` and `kubectl get pvc` to verify that both resources are Bound.

## Tip 5: Check Pod Events

If the Pod isn't running, use `kubectl describe pod tekion-pod` and check the Events section for clues.